Huntleigh DMX-R bi-directional display doppler
Designed specifically to improve efficiency and effectiveness in clinical diagnosis, DMX offers unparalleled value and quality. The bidirectional curve is generated from the digital Doppler spectrum. This provides the physician with objective evidence to support the diagnosis of vascular disease, where other Dopplers have difficulty or are unable to do so.
The algorithms optimize curve reproduction and improve sound quality using the unique Dynamic Digital Noise Reduction (DDNR) system and gel filter. Recording and playing Doppler sound are just some of the many new features of this state-of-the-art digital Doppler.
This type of DMX-R is the same as the DMX, however it comes with charger and rechargeable batteries.
Probe.
The DMX is supplied WITHOUT PROBE, these are optional.
- 4 MHz probe (01HVP4XS): for vascular doppler - for detection of deep vessels.
- 5 MHz probe (01HVP5XS): for vascular doppler - for edema-shaped limbs and deep vessels.
- 8 MHz probe (01HEZ8XS): for vascular doppler - for vessel location. Easily maintains contact with the vessels during inflation and deflation.
- 10 MHz probe (01HVP10XS): for vascular doppler - for detection of smaller vessels in specialized superficial applications.
To view this video, you first have to accept the cookies.
High-resolution color display:
- Curves displayed in high resolution.
- Wide viewing angle.
Bi-directional curve generated from the digital Doppler spectrum with auto-scaling:
- Maximizes the accuracy and clarity of curves; essential for patients with poor blood flow.
- Scroll function to review your test and choose the ideal curves.
- Arterial and venous modes.
Charging and connectivity integrated:
- USB port for easy charging and communication with software.
- Bluetooth wireless technology and connection for stereo headphones.
Interchangeable high-sensitivity sensors:
- All new XS sensors are calibrated and fine-tuned for optimal use.
- An optional PPG sensor provides simple and accurate toe pressure measurement.
Data storage on micro SD card:
- Save curves and sounds for review or transfer to optional DR5 software package for report printing and archiving.
Hear the difference:
- Thanks to digital sound processing, the new DDNR system can eliminate background noise and the gel filter reduces the loud crackling when the gel is applied.
Reliable diagnosis:
- Doppler sounds can be deceiving. Thanks to the corresponding curve, you can now visually confirm that you are interpreting the sound correctly.
Visually confirm PAV:
- An early phase of PAV can be seen by the loss of reverse current in the lower limb Doppler curve.
Venous test:
- Thanks to a specific venous mode, any reflux is clearly visible by the flow pattern above the baseline.
Immediately visualize curves for illustrated evidence.
Rechargeable:
- Charging via USB plug ensures low operating costs and no need to replace batteries.
Real-time clock:
- Allows the user to save data with a time and date stamp as proof of when the test was administered.
Educational resource:
- For educational and training purposes, one can use pre-stored files on the SD card to demonstrate the relationship between Doppler curves and sounds.
Huntleigh folder vasculair NL
Huntleigh folder foetaal NL
Huntleigh folder Fötus DE
Huntleigh folder Gefäßdoppler DE
Huntleigh fetal folder UK
Huntleigh vascular folder UK